TITLE : Diagnostic LED numbers and codes.
OS LEVEL : AIX
DATE : 07/04/99
VERSION : 1.0
----------------------------------------------------------------------------
Built-In Self-Test (BIST) Indicators
------------------------------------
100 BIST completed successfully; control was passed to IPL ROS.
101 BIST started following reset.
102 BIST started, following the system unit's power-on reset.
103 BIST could not determine the system model number.
104 Equipment conflict; BIST could not find the CBA.
105 BIST could not read from the OCS EPROM.
106 BIST failed: CBA not found
111 OCS stopped; BIST detected a module error.
112 A checkstop occurred during BIST; checkstop results could not be logged out.
113 Three checkstops have occurred.
120 BIST starting a CRC check on the 8752 EPROM.
121 BIST detected a bad CRC in the first 32K bytes of the OCS EPROM.
122 BIST started a CRC check on the first 32K bytes of the OCS EPROM.
123 BIST detected a bad CRC on the OCS area of NVRAM.
124 BIST started a CRC check on the OCS area of NVRAM.
125 BIST detected a bad CRC on the time-of-day area of NVRAM.
126 BIST started a CRC check on the time-of-day area of NVRAM.
127 BIST detected a bad CRC on the 8752 EPROM.
130 BIST presence test started.
140 Running BIST. (Box Manufacturing Mode Only)
142 Box manufacturing mode operation.
143 Invalid memory configuration.
144 Manufacturing test failure.
151 BIST started AIPGM test code.
152 BIST started DCLST test code.
153 BIST started ACLST test code.
154 BIST started AST test code.
160 Bad EPOW Signal/Power status signal.
161 BIST being conducted on BUMP I/O.
162 BIST being conducted on JTAG.
163 BIST being conducted on Direct I/O.
164 BIST being conducted on CPU.
165 BIST being conducted on DCB and Memory.
166 BIST being conducted on Interrupts.
170 BIST being conducted on Multi-Processors.
180 Logout in progress.
182 BIST COP bus not responding.
185 A checkstop condition occurred during the BIST.
186 System logic-generated checkstop (Model 250 only).
187 Graphics-generated checkstop (Model 250).
195 Checkstop logout complete
199 Generic SCSI backplane
888 BIST did not start.
Power-On Self-Test (POST) Indicators
------------------------------------
200 IPL attempted with keylock in the Secure position.
201 IPL ROM test failed or checkstop occurred (irrecoverable).
202 Unexpected machine check interrupt.
203 Unexpected data storage interrupt.
204 Unexpected instruction storage interrupt.
205 Unexpected external interrupt.
206 Unexpected alignment interrupt.
207 Unexpected program interrupt.
208 Unexpected floating point unavailable interrupt.
209 Unexpected SVC interrupt.
20c L2 cache POST error. (The display shows a solid 20c for 5 seconds.)
210 Unexpected SVC interrupt.
211 IPL ROM CRC comparison error (irrecoverable).
212 RAM POST memory configuration error or no memory found (irrecoverable).
213 RAM POST failure (irrecoverable).
214 Power status register failed (irrecoverable).
215 A low voltage condition is present (irrecoverable).
216 IPL ROM code being uncompressed into memory.
217 End of boot list encountered.
218 RAM POST is looking for good memory.
219 RAM POST bit map is being generated.
21c L2 cache is not detected. (The display shows a solid 21c for 2 seconds.)
220 IPL control block is being initialized.
221 NVRAM CRC comparison error during AIX IPL(key mode switch in Normal mode).
Reset NVRAM by reaccomplishing IPL in Service mode. For systems with an
internal, direct-bus-attached (DBA) disk, IPL ROM attempted to perform an IPL from
that disk before halting with this operator panel display value.
222 Attempting a Normal mode IPL from Standard I/O planar-attached devices specified
in NVRAM IPL Devices List.
223 Attempting a Normal mode IPL from SCSI-attached devices specified in NVRAM IPL
Devices List.
224 Attempting a Normal mode IPL from 9333 subsystem device specified in NVRAM IPL
Devices List.
225 Attempting a Normal mode IPL from 7012 DBA disk-attached devices specified in
NVRAM IPL Devices List.
226 Attempting a Normal mode IPL from Ethernet specified in NVRAM IPL Devices List.
227 Attempting a Normal mode IPL from Token-Ring specified in NVRAM IPL Devices List.
228 Attempting a Normal mode IPL from NVRAM expansion code.
229 Attempting a Normal mode IPL from NVRAM IPL Devices List; cannot IPL from any
of the listed devices, or there are no valid entries in the Devices List.
Saturday, December 15, 2007
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment